wood stove automatic air intake control

Be sure you configured and tested as explained in previous steps. How Long Do Bioethanol Fireplaces Burn For? float closeTrigger = 15000; // closeTrigger used to close vlave at end of combustion, int buzzerPort = 9; // Buzzer port, int buzzerRefillFrequency = 2000; // Buzzer tone frequency for refill alarm, int buzzerRefillRepeat = 3; // Number of refill alarm tones, int buzzerRefillDelay = 1000; // Delay of refill alarm tone, int buzzerCloseFrequency = 1000; // Buzzer tone frequency for end of fire valve close alarm, int buzzerCloseRepeat = 2; // Number of tones for end of fire valve close alarm, int buzzerCloseDelay = 2000; // Delay of tone for end of fire valve close alarm. If an exhaust fan like a kitchen range hood depressurizes the room to a level greater than the draft produced in the chimney, combustion gases will leak from any available opening, such as gaps in gaskets and the joints between factory-built chimney sections (illustration right). Air intake control, part 3 - YouTube; 3.How the air supply system works on your wood burning stove; 4.Wood stove with secondary burn. Nothing heats like this stove does! By using our website, you accept the use of cookies. the kindling and a bed of hot coals has started to be formed, the air vents on Sometimes the granite gets replaced by a big pot of lima beans or corn on the cob!On top is a small amethyst "cathedral" that I put there just because I think it looks purdy. Thank you! Woodstoves also regulate the wood fire and thus stove temperature by adjusting the combustion air intake to the woodstove at the fire door. Magnetic Top Thermometer Wood Stove Thermometer Stove Chimney Flue Pipe Thermometer Stove Temperature Meter for Avoiding Overheat (2 Pieces) . "I am entering the second heating season with my wood-burning boiler and could not be happier.I am heating over 3300 square feet and will add a hobby green house to the system this year. Forget about outdoor air supplies as a way to make wood stoves and fireplaces work better or be more efficient. every piece of wood. down the air vents until the wood stove is operating at its most efficient To Push a long hook inside the valve's hinge. water column) in normal residential installations, whereas high wind effects can produce pressures around houses up to 100 Pa. And likely, the denser cold air should compensate for some of the added heating. It worked perfectly (cannot show any pictures or drawings as he passed away over 10 years ago).Here is the idea : a small low rev fan forces fresh from the outside of the house into a pipe that runs through the stove WITH NO CONNECTION WITH THE FIRE (ie. There a pretty simple device so they work pretty good. Which woodstoves have an automatic thermostatic air control?? Wood is abundant in many parts of the Great Land, and using a renewable resource for energy makes good sense. Wood stoves are simple: air in and air out. The notification and buzzer frequency and delay can be configured in the arduino sketch. on Introduction. Brand new. Savings: $10.00. The advantage of taking combustion air directly from the room in which the stove or fireplace is installed is that the building envelope moderates the effect of wind on the air supply by damping out wind-induced pressure fluctuations. It is useful to keep in mind a key physical principle: AIR FLOWS TO ZONES OF LOWER PRESSURE through any available opening. If we close the damper on the stovepipe, the fire slows down. In general, therefore, wood stoves and fireplaces that are vented by natural chimney draft should draw the air for combustion from the room in which they are located. Calibrate the zero angle of the servo motor. Just set the stove for the heat output you want and let the thermostat do the rest. Woodstove fan systems are rated based on the volume of air they can move per unit time. Build a prototype to use on a Drolet HT-1200, adjusted the PID data keep the temperature from dropping too much, works great! on Introduction, Do you know how much heat you're losing out of the flue? Yes, a lot. - After tossing around many, many ideas that eventually got dismissed because of complexity or cost or being a pain to remove every time I wanted to add wood, I thunk this one up. Wood burning stoves help to increase the Sign up for our Newsletter to receive updates & promos. I would like to commercialize this in South Africa. the wood and reducing the total heat of wood too early into a fire can smother the fire if it isnt yet hot enough. An example of data being processed may be a unique identifier stored in a cookie. I still have to reset the potentiometer to get rid of the message. And the process of feeding oxygen to the fire goes on as usual. Wind effects around the house also affect the direction and volume of flow through a passive inlet. Price: $239 5. Our next project will be installing the domestic hot water coils in the spring. The thermocouple is represented by a square on the left. The Arduino sketch is open source and available for download, please read the header before using it. Your comment are right on. Do Bioethanol Fireplaces Need Electricity. to go out completely. Start a fire, check the temperature. Its a dance. You can get some nice PID curves by getting the values with Arduino serial port and plotting them. Simply, easily and automatically. Wood stove air intake control. By opening the wood stove damper, it allows air to get into the chimney so the fire can start. Progress Hybrid 209 Maintenance Kit.. $55.00. Call to hear more about our Sale: $140.00. If the fire is burning too quickly, simply Thanks for the design and the code.I have installed it on my stove and it works good the regulation is good. Company . I something goes wrong, use the potentiometer below 80% to be in manual mode or use the manual control of your wood stove. but closed down enough so that enough air is being supplied to the fire to keep EPA certified at 1.6 g/h, this non-catalytic appliance represents an eco-responsible heating source. maximum efficiency or maximum heat output. or Best Offer. 2 years ago Save my name, email, and website in this browser for the next time I comment. Everything done right and approved by the insurance company. ELIGIBLE FOR THE 25D WOOD STOVE TAX CREDIT >> Mansfield. FlexBurn Technology. Thread starter sccron; Start date Dec 2, 2010; S. sccron New member . The extent of building depressurization is deducted from potential chimney draft, like this: theoretical draft depressurization = net draft. Behind the chunk of granite is a pile of aluminum ingots from my backyard foundry. In Indoor Fireplaces, Wood Burning Stoves by James O'KellyJanuary 2, 20208 Comments. Did you type thermostat into the search bar? Hello I find your regulatory program excellent and I hasten to implement it for next winter. I was thinking that you could pipe from that floor register directly outside through the wall, and further reduce a little of the heat loss from your house. Then make a firewood and check the thermocouple and the valve behaviour (by simulating the air admission with your stove manual controller) To put the Arduino regulator in automatic mode, you have to put the potentiometer to 100%. Ashley Hearth Products 3200 Wood Stove. More if you consider that hot air takes up more space than room temperature air. Generac GP17500E 17500W/26250W Gas . A stove vented by natural draft needs a reliable and unrestricted supply of combustion air. If, on the other hand, the passive inlet is located above the house neutral pressure plane, air will flow out. on Introduction. After viewing product detail pages, look here to find an easy way to navigate back to pages you are interested in. Starter LS. Share it with us! Its a big advantage to choose a wood burning stove wih an automatic control device. Thank you gor your in depth description of proper wood stove operation, it is very informative. The wood boiler was one of the best decisions I have made. Ventis Blower with Variable Speed Control for HES140 Stoves; Ventis Rigid Fire Screen for HE325 Fireplaces; Ventis Forced Air Kit for ME300, HE250R, HE275CF, HE325, ME150, and ME300 Fireplaces . Quickview. Both notification are based on the integral of the PID to be more accurate (than notifications based on temperatures). 42 sold. To view the purposes they believe they have legitimate interest for, or to object to this data processing use the vendor list link below. If the chimney and the firewooddiffer much from the standard chimney and firewoodyou will have to adjust the automatic control device (which is often done simply by turning a screw). ---The main reason for having a dedicated air-inlet is to control WHERE the combustion air comes into the house. This way you'll make the most of your firewood and you'll protect the environment as much as possible. Hello,I was really inspired by this project and decided to do something to my wood burner as well. Our Products. We are grateful for your promptness and ease of coordinating! In manual mode the air distribution can be controlled in each combustion phase-even in the event of a power outage. The boiler requires very little maintenance and is simple to operate. going. on Introduction. $6.50 shipping. Chimney draft ranges from zero to about 50 Pa (0.2 in. it going quickly and get the stove up to operating temperature. We used the stove a lot and never had any issues with air draw. A wood burning stove with an automatic control device automatically regulates the air supply. New posts Search forums. You can install the Adafruit's library from Arduino's IDE. Question Please note that they are all printed in ABS, you might update printing size for other materials. The worst-case indoor air pressure environment can be measured using the house pressure test procedure, and can be controlled either by limiting exhaust flows or by installing a powered make-up air system. Thanks phicoI could not get the program to use the the temperatureMin at all the errI would keep increasing when above the setting of the temperature Min I made the change to the code below and now when the temperature is below the temperatureMin setting the errI starts counting then and completes the cycle and it now works perfect // Close end fire if (errI >= closeTrigger) errI = closeTrigger; if (temperature < temperatureMin) errI = 0; // I changed the < less than to > more if (errI >= closeTrigger) drawing = zeroDrawing; than I also added a relay that controls the fan on the stove and a potentiometer so I can adjust the consigneTemperature because on a colder or warmer day it keeps the room temperature more even, Question Why Stoves Are Usually Black Not White? Chimney draft control - damper: to the fire, and also start to slowly 129 Goodfellow LaneHowes Cave, New York 12092. Continue with Recommended Cookies. Thanks, Many thanks for these articles-we are about to start the building work to install process our first wood burner and now have the information to confidently deal with the installation company. It is highly recommended to test the system before deploying it .. The U.S. Department of Energy anticipates three times as much energy will come from wood in the future. If you keep the damper open, the fire will build and the smoke and soot will vent through your chimney. 1 year warranty. Our family has an old vacation property in upstate NY that was FREEZING cold during the winter that we stayed there, and it was because of the negative pressure and air leaks that you mentioned. tips.adurofire.com was made to inspire, inform and unite people who have an interest in wood burning stoves. on a wood burning stove to control a fire. Ideally, a stove operating on natural draft takes its combustion air from a neutral pressure environment so that the air supply is steady and consistent. Close it for long, efficient burns. flames going again. are fully open. The aim at the start of any fire is to get IntelliFire Touch Controls. Since the air consumption of a wood stove is so low, the risk of reversal of a ducted combustion air supply outweighs any advantage gained by bringing air from outdoors. If the fire becomes too strong, the valve should close again. Smoke leakage can occur, even when the appliance has tightly sealed doors. With the patented Aduro-tronic automatic control, the primary air supply is automatically regulated, so you do not have to regulate the combustion. A lack of air can also cause the fire Oops! It is sometimes assumed that taking air from outside through a duct saves energy because the stove doesnt use up indoor air and cause outdoor air to be drawn in through leaks to replace it. Any other stoves out there with this feature? A wood stove without a flue system attached will not function properly. it going, without causing it to smolder. Ontario Lakeside 13.1K subscribers 36K views 1 year ago Adding a cold air intake can significantly improve the heating capacity of. Thanks! Ive been running a wood stove off and on since 1966. If the vents on a wood stove are open too Flush Wood Insert. Adding larger sized pieces However, it is also possible for a passive supply to cause spillage if air is drawn out of the house into a low pressure zone caused by wind effects. gets going, how quickly it burns through the wood, and how much heat is There are two ways to do that: When the flames are burning brightly, youll remove the key and leave the rest to the automatic control device. Aug 28, 2020. If the fire starts to dim and diminish while you approach the vents, leave them open slightly and try again. There may be circumstances in which a direct outdoor air supply is considered necessary. Free shipping. closed, the fire will be starved of oxygen and start to smolder, and can end up air vent that is located underneath the stove, while there are also air vents We and our partners use cookies to Store and/or access information on a device. Increase Efficiency - Decrease Air Pollution and Creosote. Going to bed. Although more heat will be produced, the rate at down this main vent reduces the amount of oxygen getting to the fire, therefore decreasing how fast the fire burns through on Introduction. Learn More Expertise through our longevity How much Ohm are they? There seem to be three theories behind this outdoor air supply, depending on who is doing the explaining. You describe two different air vents on your stove - it may be that one of these provides external air to the upper part of the stove, which will help burn the wood gases more effectively - open this a little and observe your smoke stack to see what effect it has. The kennel buildings have never been so warm. The wood burns more slowly as a result. to never build the fire higher than these vents. This last factor makes the biggest difference in making this kind of system more efficient. until it was studied, Direct-to-combustion chamber outdoor air supplies, Awair element indoor air quality monitor aqm8002a, Air fryer trader joes cauliflower gnocchi. A fire inside will tend to smolder, and the air control settings will have little impact on the burn rate. Just a bit of labor to cut it up and split it. I think that this would go a long way towards a remedy. For use of a fireplace as a backup heat source during power outages, ensure that. This way you will get the most out of the firewood, save money on heating your home and you're guaranteed eco-friendly combustion. L'ensemble est mont, mais je n'arrive pas avec le codage du programme, en fait l'cran lcd s'allume mais aucune indication sur celui-ci. And you may also benefit from increasing kI to allow it to start increasing/decreasing the drawing % sooner when the current drawing isn't having much impact.Again, thanks for this PID code. If you would like to change your settings or withdraw consent at any time, the link to do so is in our privacy policy accessible from our home page.. Back when I used central heat, there was a 4" x 10" heat register mounted in the floor right behind where my stove is located now. be used throughout the duration of a fire to help control how quickly the fire The GermanTechnologie- und Frderzentrum made a survey as a part of the project called beReal of how wood burning stove owners really fire in their wood burning stoves. Closing In this blog, we discussed how to control the air flowing into your wood stove for more efficient burning and warmth. For me I watch the coals, keeping them under control controls the heat. I can see why comfort might increase quite a bit but not efficiency. Here is another contraption my father made a long time ago. JavaScript is disabled. If you find that you're having it fire too hot (above target temperature), you should probably change kP to something lower than 5 (5 was the default value). Wondering if you have any objections for doing it this way. on Step 1. u didnt know this but if u put a small chunk of live ember into that amethyst. The revolutionary design of the GW1949 allows it to provide silent heat without the need for any electricity. At the end of the fire, the system automatically close the air supply to prevent the stove to cool down to fast. Standby. Hello, please check the diagram and your module doc. In the fire in your wood burning stove is Peut tre que votre aide pourra dbloquer mon problme si cela ne vous drange pas bien sur. The most obvious alternative is to take combustion air from inside the building. on Step 5. How Many Watts Does An Electric Stove Use, How Long Does It Take For An Oven To Cool Down. Would you be open to this? 11 years ago A lot of the work of the heater was going toward heating that cold air! Much appreciated. $14.99. To many coals makes it run hotter and run the risk of a chimney fire. . This is such a great project! If the air supplyis controlled by the temperature of the smoke, the advantage is that you wont have to take differences in chimneys into consideration. I have seen people put a coil of copper pipe on the stove, then run it over to a radiator with a pump and a fan on the radiator.warms 2 places at once, 13 years ago This means less work, less wood use and an improved combustion. Where necessary the indoor air pressure should be controlled to minimize depressurization. The average air consumption of a modern wood heater is in the range of 10 25 cfm, which is very small compared to the natural leakage rate of houses. Share it with us! By using this project you take all responsibilities of its configuration, implementation and usage. Outdoor combustion air was a good idea . Chimney or flue has been cleaned and inspected for cracks, damage, animal debris, and creosote buildup. The consent submitted will only be used for data processing originating from this website. close down the air vent as the fire progresses without causing the fire to Flap is normally close!. It's necessary since the thermocouple will be touching metal (your stove/pipe).I wanted to share this for any others who are attempting an implementation. For a better experience, please enable JavaScript in your browser before proceeding. The wood doesn't just disappear. A fire requires Buy Now. We have been heating 4 buildings this winter with the new boiler. It is this individual attention together with a quality product that makes us one of the nation's oldest boiler and furnace manufacturers. Successfully and efficiently operating a wood stove is definitely a learning process so I appreciate the time you have put into this clear and concise article. On the other hand if the vents are too far It looks so much like the foil of the hose that you can't tell where one ends and the other begins. You can also add a stack robber on the flue pipe- this helps capture lost heat. A Pocket Sundial From a Broken Pocket Watch! Not sure why all stoves dont have one. What is a secondary air tubes wood stove? Depending on your model of wood burning a potentiometer to control manually the air supply. Leave the new damper closed. ACC technology delivers precision start-up and air control for consistent burns. Good Day, how is this working now. Exactly what i'm looking for. $120.00. 3. The Fox II stove features manual and automatic control settings. close down the main air vent in small stages until the fire is burning slowly The technology behind the devices varies. 12 years ago The trigger values must be configured in the arduino sketch. Well, um, so yes, probably. Outdoor air supplies connected directly to the stove or fireplace combustion chamber may seem like a good idea and it was once believed that a direct supply would isolate the combustion appliance from room pressure variations. Kitchenforemost.com is working under Amazon Services LLC Associates Program. Wyld Bill Feb 12, 2011 Active since 1995, Hearth.com is THE place on the internet for free information and advice about wood stoves, pellet stoves and other energy saving equipment. handle away from the stove, while pushing the handle towards the stove closes burning through the wood. The message does not seem to work with the control for the valve. You are using an out of date browser. You need to open up the primary air control all the way and burn the stove hot for about 20 min, get the chimney good and hot to establish a good draft and then shut the air control down. Can anyone give advice on putting the fire out completely? I do think that a carbon monoxide detector is vital for any stove burning fuel. The flue collar of a wood-burning stove sits below the cap and above the firebox. L, I love your stove and your big granite rock ! Do you have any updates. Wood burners consume combustion air in response to the amount of chimney draft produced by the heat of their own flue gases. 2005 Defiant 1610 on my first made stone hearth & stone faced chimney. located on the back of the stove that cant be controlled. A passive make-up air supply is really nothing more than another uncontrolled leak in the house envelope. Forums. But direct combustion air supplies cannot effectively be connected to a fireplace without doors because insufficient pressure difference is created to drive the flow. Potentiometer are 10k you can find in most Arduino kits. In fact I remember having tested the room for leaks and see a piece of cigarette paper being slightly sucked out ! (a teen ager never believe his pa ! This is 6" flexible foil dryer vent hose that you can get at most any home improvement store. The maintenance kit includes the top lid gasket (pre/post 2005), air duct c.. $55.00. Some of our partners may process your data as a part of their legitimate business interest without asking for consent. AC01331 FRESH AIR INTAKE KIT. Buy Now. I'll come edit this if I adjust anything.Also, to everybody implementing this, USE AN UNGROUNDED THERMOCOUPLE. ).This has worked for more than 40 years and was still in operation when we had to sell the house.If this experience can help I'll be glad !, 12 years ago supply to the fire and therefore increases Because these air supplies were invariably routed straight down into the ventilated crawl space under the mobile home, they didnt cause too many problems, so it was assumed that they actually worked. At this point we like to add a further log We and our partners use data for Personalised ads and content, ad and content measurement, audience insights and product development. a wood burning stove can be used to ensure that the fire remains going When servicing systems with direct outdoor combustion air ducts, look for soot or staining inside the duct. If you haven't already created a layer of ash at the bottom of your stove's burn box. I have a vague idea that it would be good to use the flue gas to pre-heat your air intake, via some kind of heat exchanger, but not much more than that. Slowly start to close down the vents once the fire has caught hold of the kindling. The placement of thedeviceinside the fire box also reducesthe reliability because of high temperatures and soot, and maintenance and service will be made more difficult. If you do not have an outside supply, it will pull it from inside the house which will depressurize the house and the fire will burn poorly. 1 year ago located at the back of the firebox. A lousy draft = a smoky wood burner or fireplace with a lot of the smoke ending up indoors.My old house is nowhere close to being tightly sealed. down in small steps to bring the fire back to being its most efficient. 12 years ago 9 years ago You should consider doing so because thats the best way for wood to keep burning consistently. View Details. Disclaimer : I am not responsible of any use of this project. smolder or go out. How do I control the airflow in my wood stove? System matched to a 40 gallon Superstore tank. Thank you! we installed it before we spray foamed. Read more about why firing with firewood is carbon neutral. Thank you very much for your expert work and assistance with our stove. If the chimney wins the competition, the flow direction is up (successful venting); if the fan causing the depressurization wins, the flow is down (spillage or backdrafting). Is it to prone to problems? Much of what is going up the chimney is exhaust from the wood itself but the fire needs to pull oxygen from somewhere. Simply, easily and automatically. Evidence of wind-induced reversals in combustion air ducts is becoming more common now that so many systems have been installed. Not providing enough air supply to stove is dangerous. I used 4" rigid galvanized vent pipe for the outside air, total length was about 14' (4' horizontal and 10' vertical.) Because air flows to zones of lower pressure, a tightly sealed combustion/venting system will spill a smaller volume of smoke into the room than a leakier system, but it will still leak unless it is perfectly sealed. Any information would be greatly appreciated. Drolet 5" Fresh Air Intake Kit For Wood Stove On Pedestal New. ? It will take a little while to find the right setting on the damper not to open not to closed. Unfortunately, the decision to enforce mandatory outdoor air rules was made before research was done to investigate how they actually work. 9 years ago Building depressurization competes directly with chimney draft. A remedial strategy that only works sometimes, and that may make the problem worse, is not a good strategy. Zone Damper 8" Round Professional-Grade (HVAC Zoning) - Preminum replacement for Honeywell, EWC, Durozone, more (08), Chimney 69128 6 Inch Dura-Vent DVL Double-Wall Stove Adaptor With Damper Section, DuraVent 6DBK-ADSL Snap-Lock Adapter with Trim for DuraTech/DuraPlus/DuraLiner Chimney Connections, 6", FIREHIKING Stovepipe Spark Arrestor Chimney Rain Cap for 2.36inch/6cm Stainless Steel Stove Pipe, Vermont Castings Ceramic Fallaway Handle Assembly (White with Nickel Nub) 0004342, JIMBON 6 Blade Small Wood Stove Fan Heat Powered Silent Circulation Fireplace Fan for Wood Burners Stove Log Burner Operation Eco Friendly Efficient Heat Distribution With Thermometer, US Stove DR6 Barometric Draft Regulator, 6-Inch, SoloWilder Stovepipe Spark Arrestor Male-Head Version 2.36 inch Chimney Rain Cap 18.7cm/7.4in, SoloWilder Transposed Stovepipe Female-Female Version 2.36 inch Flue Connector Stainless Steel, Magnetic Wood Stove Thermometer Fire Stove Pipe Thermometer Flue Pipe Temperature Meter for Avoiding Stove Fan Damaged by Overheating (2), Hi Flame Coated Sand Casting Cast Iron Fireplace Ash Dump Door, Midwest Hearth Wood Stove Replacement Gasket for Woodburning Stoves - Graphite Impregnated Fiberglass Gaskets (5/16" x 84" Rope), Moisture Meter For Wood - Pin Type Digital Dampness Moisture Sensor Detector For Wood, Firewood, Brick, Drywall, Paper, Floor, Plaster - User Friendly Accurate Woodworking Moisture Gauge, VODA 4-Blade Heat Powered Stove Fan for Wood / Log Burner/Fireplace increases 80% more warm air than 2 blade fan, GALAFIRE Magnetic Stove Thermometer Oven Temperature Meter for Wood Burning Stoves Gas Stoves Pellet Stove Stoves Avoid Stove Fan Damaged by Overheat, CXhome Heat Powered Stove Fan for Wood, Fast Start, 4-Blade Fireplace Fans, Ultra Quiet, Increases 80% more Warm Air, Energy Saving, Carbon Emission Reduction, Flat Gasket Tape for Stoves and Fireplaces, Self Adhesive Flat Gasket, 5/8"x1/8" Length 72" Wood Stove Flat Gasket Tape, Vermont Castings Black Wooden Handle 1600664, Magnetic Top Thermometer Wood Stove Thermometer Stove Chimney Flue Pipe Thermometer Stove Temperature Meter for Avoiding Overheat (2 Pieces), BBQ Smoker Supply wood stove ajustable grill vent damper 8" inch firebox QTY1 AL .#GG4346 43ETR98-Y530974, Vermont Castings 5004265 Damper Handle Stub, Stanbroil Magnetic Wood Stove Pipe Thermometer, Flue Pipe Temperature Meter for Wood Log Chimney Pipe, Metal Fireplace Damper Pull with Solid Brass Handle, Jamborum Backdraft Damper 4 Inch Round Prevent Unwanted Drafts in Metal Ducts Professional-Grade, Heavy Duty Galvanized Steel with Aluminum Flaps Spring-Loaded, One-Way Airflow Insert, Stanbroil Graphite Impregnated Fiberglass Rope Seal and High Temperature Cement Gasket Kit Replacement for Wood Stoves - 1/2" x 84", TWO PACK 2 BBQ Smoker Supply wood stove ajustable grill vent damper 8 inch Aluminium, Apipi 2 Pcs Wood Stove Gaskets, High-Temperature Resistance, Graphite Impregnated Fiberglass Replacement Gaskets Tape Self-Adhesive for Smokers Woodburning Coal Stoves (11/16" x 3/16" x108" in Total), iPower 6 inch Backdraft Shutter Damper Back Draft Blocker, One-Way Airflow Ducting Insert Backflow Preventer with 2 Inline Springs Loaded Folding Blades, 6", for HVAC Extractor Fan Vent, Range Hoods, Wood Stove Thermometer, Foedo Magnetic Thermometer for Wood Burning Stoves Gas Stoves Pellet Stoves, Helps Monitor Temperature and Avoid Overheating of Stove Fans, Vermont Castings 7001148A Grate for Dutchwest 2462, M&G DuraVent DURAVENT 6DBK-E90 6" DuraBlack 90 Degree Elbow, Black, Wood Stove Thermometer Magnetic, Oven Stove Temperature Stove Top Thermometer for Wood Burning Stoves, Gas Stoves, Pellet Stove, Avoiding Stove Fan Damaged by Overheat, AC Infinity 8 Backdraft Damper, One-Way Airflow Ducting Insert with Spring-Loaded Folding Blades for 8 Ducting in Range Hoods and Bathrooms Fans, Vent Systems 6'' Inch Backdraft Damper - Backflow Shutter - Heavy-Duty Inline Springs Loaded - One-Way Airflow Ducting Insert - Inline Fan Vent Deflector, Fireplace Tools Sets for Your Home by Amagabeli.